Electric Motor Repair
Is your motor missing from the list? We'll still fix it.
- Call A&C Electric for repairs (586) 469.0710 -
Electric Motor Repair in Lansing, MI
A&C Electric is Lansing Michigan’s leading electric motor repair company. With all the equipment and expertise necessary to repair all types of electric motors, choose A&C for fast and professional electric motor repair. We will have your new motor running like new and back to you in no time! Contact us today to discuss the repair process, turnaround times, and get a free quote!
Fast Turn-Around Electric Motor Repair
Our repair process entails a detailed diagnosis, repair, and testing. Everything is completed on-site and efficiently, meaning exceedingly fast turn-around times. Downtime is the bane of efficient operations. Minimize downtime and save money with electric motor repair services from A&C Electric.
Contact A&C Electric today for a free quote on electric motor repair!
Servo Lab Capabilities




Servo Lab Repair Procedures
-
Data
Motor nameplate data is recorded
-
Inspection
A visual inspection of any damage to the motor.
We check for- Damaged Leads/Terminals
- Worn output shaft/keyways
- Cracks in end bells or covers
-
Job Ticket
We complete to full write up off all motor data
Including- All winding tests (Resistance, Meg Ω, Continuity)
- All bearing sizes
- All seal sizes
- Brake torque tests (Record Torque, winding resistance)
- Feedback Tests (Tachometer/Encoder)
-
Motor Disassembly
- Bearing and seal sizes are recorded
- Bearing fits are measured on shaft and End bell
- Brake torque is measured as well as resistance and Meg Ω
- More winding tests are performed (Surge and HiPOT tests)
- Stator is then washed and baked in oven
- Magnets are inspected for cracks or if loose on shaft
- Encoder is tested with either (Heidenhain PWM20, Sick PGT-11, or Mitchell Electronics equipment)
-
Assembly
- New bearings are installed
- New seals are installed
- If required, new windings are impregnated
- Brakes are rebuilt or replaced depending on manufacturer design.
- Rebuilt or New encoders are installed and aligned using:
- (Heidenhain PWM20, Sick PGT-11, or Mitchell Electronics equipment)
-
Rotor Balancing and Testing
- Rotor is run through a full vibration diagnostic
-
Run Testing
- Every Motor is Run for a minimum of 1 hour using one of our drives.
- We use Siemens S110, S120, IndraDrive, AB Kinetix 300, Yaskawa 7, and AMC drives
-
Service Report
- A Final 3-page Service Report is filled out
- Pinout diagram for power and feedback is provided
- Brake torque is recorded a final time for our Service Reports
- A photo of nameplate and motor is attached
- A motor tag is installed on motor with QR code linking Service Report and Job Histories
- If requested, a YouTube link is attached to the service report of motor